Our exam materials can be trusted
We have been collecting the important knowledge into the HFDP learning materials: Healthcare Facility Design Professionals over ten years and the progress is still well afoot. So it is a best way for you to hold more knowledge of the HFDP actual lab questions. Owing to our special & accurate information channel and experienced education experts, our HFDP exam preparation get high passing rate and can be trusted. By spending up to 20 or more hours on our HFDP certification training questions, you can clear exam surely. About the updated versions, we will send them to you instantly within one year, so be careful with your mailbox.
After purchase, Instant Download: Upon successful payment, Our systems will automatically send the product you have purchased to your mailbox by email. (If not received within 12 hours, please contact us. Note: don't forget to check your spam.)
It is a lifetime study time. The society advocates us to further our study and improve working skills at every aspect. For exam candidates like you it is of great importance to pass the ASHRAE exams effectively. That is why we offer you the excellent HFDP learning materials: Healthcare Facility Design Professionals compiled by professional experts. Now, let us take a comprehensive look of the features of the HFDP actual lab questions as follow:
Great exam materials for customers
We have been trying to win clients' affection by our high quality HFDP learning materials: Healthcare Facility Design Professionals and we realized it in reality. So they affirm that our HFDP exam resources are professional in quality and responsible in service. If you are afraid to trying, you may lose the chance to accept the excellent HFDP actual lab questions and pass exam smoothly. If you blindly choose the practice test questions on the market, you may need to start to prepare the test afresh. So the former customers are agreeable to the quality of our exam materials edited by experts elaborately, and you can trust us that our HFDP practice test: Healthcare Facility Design Professionals are an effective aid for your exam.
Aftersales services for customers
Many former customers are thankful for and appreciative of our HFDP exam materials. We always offer assistance to our customers when they need us and offer our help 24/7. The most important is our employees are patient to deal with your need about HFDP learning materials: Healthcare Facility Design Professionals at any time. They always treat customers with curtesy and respect. So you can contact with us if you have problems. There are so many former customers who appreciated us for clear their barriers on the road, we expect you to be one of them and pass the test like a piece of cake. Our HFDP actual lab questions can help you practice & well prepare for your test so that you can pass real exam easily. So do not need to hesitate and purchase our Healthcare Facility Design Professionals study materials, you will not regret for it.
ASHRAE Healthcare Facility Design Professionals Sample Questions:
1. Which of the following combinations in an HVAC system increases the risk for the spread of healthcare- associated environmental pathogens?
A) Stagnant air and outdoor fungi
B) Stagnant air and moisture
C) Accumulation of dust and moisture
D) Accumulation of dust and outdoor fungi
2. An airborne infection isolation (AII) patient room has a volume of 1,100 cubic feet (31.15 m³) and requires a minimum supply airflow of 12 air changes per hour (ACH). Airflow across the door to maintain pressurization is 150 CFM (70.8 L/s). Leakage and toilet room exhaust is 130 CFM (61.4 L/s). What airflow should the exhaust fan serving the patient room and toilet room be sized for?
A) 370 CFM (174.6 L/s)
B) 500 CFM (236.0 L/s)
C) 70 CFM (33.0 L/s)
D) 150 CFM (70.8 L/s)
3. Replacement of existing roof membranes, replacement of existing doors, and replacement of less than 25% of existing windows are exempt from complying with ANSI/ASHRAE/IESNA Standard 90.1-2004 in which of the following situations?
A) The hospital is in climate zone 1 and has typical energy use
B) The hospital does not accept payment from CMS for energy costs
C) The hospital is non-profit and pays no taxes on energy
D) The replacement causes no increase in energy use
4. The following information refers to the diagram above.
The following information refers to the diagram above:
* The room is an Airborne Infection Isolation Room with a series anteroom.
* The room volume is 960 cubic ft. (27 cubic m).
* The room cooling load is 4,000 Btu/hr sensible only. (Ignore latent loads.) (1172 W)
* The supply air temperature is 55° F (12.8° C), and the room temperature set point is 75° F (23.9° C).
* The toilet exhaust is 100 cfm (47.2 L/s).
* The total room envelope leakage area is 35 sq. in. (22.575 sq. cm), (A_L).
* The anteroom supply air volume is 75 cfm (35 L/s).
* The design pressure difference complies with FGI Guidelines (D_p) (in. water/kPa).
* The room air flow difference (Q_d) is defined by the following:
Q_d = (7p)^0.65 x A_L / 0.019564
(SI) Q_d = (7p)^0.65 x A_L / 10,000
Based on the diagram and the information above, what is the MINIMUM design room air exhaust volume?
A) 100 cfm (48 L/s)
B) 250 cfm (117 L/s)
C) 300 cfm (142 L/s)
D) 75 cfm (35 L/s)
5. Which of the following is a key function of an Infection Control Risk Assessment process when applied to a hospital renovation project?
A) Determining probable pathogens
B) Identifying building construction timeline
C) Identifying construction area location
D) Determining contractor qualifications
Solutions:
Question # 1 Answer: C | Question # 2 Answer: A | Question # 3 Answer: D | Question # 4 Answer: B | Question # 5 Answer: A |